Graco Inc. Glascraft GC-1388G Manual de usuario

Busca en linea o descarga Manual de usuario para Rociador de pintura Graco Inc. Glascraft GC-1388G. Graco Inc. Glascraft GC-1388G User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Operation
Indy-X Chop GC-1388G
ENG
Important Safety Instructions
Read all warnings and instructions in
this manual. Save these instructions.
Low emission external-mix dispense gun for use with polyester resin and gel coat.
For professional use only.
Maximum fluid working pressure:
2000 psi (14 MPa, 138 bar)
Maximum air pressure:
100 psi (0.7 MPa, 7 bar)
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - GC-1388G

OperationIndy-X Chop GC-1388G ENGImportant Safety InstructionsRead all warnings and instructions in this manual. Save these instruct

Pagina 2 - Contents

10 GC-1388F 23575-00 Indy X Chop Dispense GunNote:Use p/n: LPA2-123S and p/n: LPA2-124Swhen using LPA2-147-XXXX and 23047-XX series spray tips

Pagina 3 - Changing Materials

11GC-1388F 23575-00 Indy X Chop Dispense GunAssembly Drawings

Pagina 4 - Warnings

12 GC-1388F 23575-00 Indy X Chop Dispense GunAssembly Drawings

Pagina 5 - Important Safety Information

13GC-1388FPartnumberDescription Qty.11021-41 PIPE PLUG 213076-06 O-RING 113867-03 O-RING 113867-05 O-RING 113867-07 O-RING 313867-09 O-RING 115845-01

Pagina 6 - Grounding

14 GC-1388F To relieve uid and air pressures: 1. Push down Yellow slide valve, P/N 21402-00 to bleed off air to system.

Pagina 7 - 7GC-1388F

15GC-1388FParts Replacement ProcedureBefore performing maintenance on the dispense gun, follow Pressure Relief Procedure.Due to the different o-ring m

Pagina 8 - GC-1388 User Manual

16 GC-1388F12345Needle & Pin Removal Procedures1. Remove needle collets. (3/8in. Wrench)2. Remove set screws. (5/64in. Hex Key)3. Remove needle g

Pagina 9

17GC-1388F21222-0020507-00(Retainer) If Packing, P/N 20507-00 and Packing Disks, P/N 20508-00 are removed from Needle and Pack-

Pagina 10 - Assembly Drawings

18 GC-1388FOKOK53421FlushNeedle & Pin Reassemble Procedure1. Reassemble the needle assemblies to the gun body. Lubricate the o-rings & use te

Pagina 11

19GC-1388FNOT OKSet Screws 5/64in. hex keyTrigger & Needle Guard Readjustment ProcedureIf you trigger the gun and notice that one needle is activa

Pagina 12

2 GC-1388FContentsWarnings ... 3Important Safety Information ... 5Groundi

Pagina 13

20 GC-1388F1Remove the triggerfrom gun. Slide itdown and to the side. 2Slide the gun pins, p/n 23514-00 forward to allow acces

Pagina 14 - Pressure Relief Procedure

21GC-1388FPartNumberOrice Min.Width (in.)Max.Width (in.)Min.Output (lbs.)MaxOutput (lbs.)23005- C40.040 7 16.5 5.4 10.02 C50.050

Pagina 15 - Maintenance

22 GC-1388F Impingement Dispense Tip Reference Chart Airless Dispense Tip Reference ChartPartNumberOrice 23047-J1 .012

Pagina 16

23GC-1388FTechnical DataCategory DataMaximum Fluid Working Pressure 2000 psi (13.8 MPa, 138 bar)Maximum Air Inlet Pressure 100 psi (.69 MPa, 6.9 bar)T

Pagina 17

Graco Ohio Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free fr

Pagina 18

3GC-1388FWarnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point

Pagina 19

4 GC-1388F WARNINGSKIN INJECTION HAZARD High-pressure uid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a

Pagina 20 - 2

5GC-1388FImportant Safety InformationMethyl Ethyl Ketone Peroxide (MEKP) MEKP is among the more hazardous materials found in commercial c

Pagina 21 - 21GC-1388F

6 GC-1388F This equipment needs to be grounded. Ground the dispense gun through connection to a GlasCraft approved grounded uid supp

Pagina 22 - 22 GC-1388F

7GC-1388FRotate trigger lock to stop the triggerfrom being activated. Hose Attachment 1. Engage the trigger lock. 2. Attach the (blac

Pagina 23 - Technical Data

8 GC-1388F Indy-X Chop Dispense Gun 23575-00 Repair Parts Kits:Part NumberDescription23557-00 O-RING KIT23558-00 MAINTENANCE KITStandard Equip

Pagina 24 - Graco Ohio Information

9GC-1388F1231) Catalyst seat assembly p/n: 23544-002) Material seat assembly p/n: E-1353) Material needle valve assembly p/n: 23545-00 23575-00 In

Comentarios a estos manuales

Sin comentarios